Fixed-mounted thermal imaging cameras like the FLIR A310 thermal imaging camera can be installed almost anywhere to monitor your critical equipment and other valuable assets. It will safeguard your plant and measure temperature differences to assess the criticality of a given situation. This allows you to see problems before they become costly failures, preventing downtime and enhancing worker safety.

The FLIR A310 contains an uncooled Vanadium Oxide (VOx) microbolometer detector. It produces crisp thermal images of 320 x 240 pixel and detects temperature differences as small as 50 mK. The A310 comes with a built-in 25° lens with motorised focus. Other fields of view are available.

Stream MPEG-4 video over Ethernet to show live images on a PC. 640x480 with overlay up to 30 Hz. Ethernet-enabled, communication and power can be supplied with only one cable. Composite video outputs, PAL and NTSC compatible are available. Both cameras can be controlled remotely over the Web using TCP/IP protocol. The FLIR A310 comes standard with built-in analysis functions like spot, area measurement and difference temperature. Alarms can be set to go off as a function of analysis, internal temperature or digital input. The camera automatically sends analysis results, IR images and more as an e-mail on schedule or at an alarm. Autonomous dispatch of files or e-mails, acting as an FTP- or SMTP-client is possible.

Features:

System OverviewFLIR A310
Spotmeter10
Area10 boxes with max./min./average/position
Isotherm1 with above/below/interval
Measurement optionMeasurement Mask Filter Schedule response: File sending (ftp), email (SMTP)
Difference temperatureDelta temperature between measurement functions or reference temperature
Reference temperatureManually set or captured from any measurement function
Atmospheric transmission correctionAutomatic, based on inputs for distance, atmospheric temperature and relative humidity
Optics transmission correctionAutomatic, based on signals from internal sensors
Emissivity correctionVariable from 0.01 to 1.0
Reflected apparent temperature correctionAutomatic, based on input of reflected temperature
External optics/windows correctionAutomatic, based on input of optics/window transmission and temperature
Measurement correctionsGlobal and individual object parameters
Field of view (FOV) / Minimum focus distance25° × 18.8° / 0.4 m (1.31 ft.)
Lens identificationAutomatic
Thermal sensitivity/NETD< 0.05°C at +30°C (86°F) (86°F) / 50 mK
FocusAutomatic or manual (built in motor)
F-number1.3
Image frequency30 Hz
Zoom1–8× continuous, digital, interpolating zooming on images